Product Details:
|
Product Name: | Small SS Filter Press | Material: | 304/316L |
---|---|---|---|
Feed Pressure: | 0.6 MPa | Type: | Fame And Plate |
Plate Material: | SS316/304 | Filter Precision: | 0.22/0.45 Micron |
Plate Shifting: | Manual | Contorl Method: | PLC |
Beam: | SS304/316 | Close Method: | Mechanical |
High Light: | Manual small filter press machine,palm oil filter press,small filter press |
Stainless Steel Manual Small Filter Press for Edible Oil
Press filter, SS mobile filter press small filter press filter, is widely used in many fields. ZL horizontal plywood frame filter press, for low concentrations of 50% or less viscosity, less the amount of slag containing liquid as a sealed filter to achieve purification, sterilization, clarification and other fine filter, activated carbon removal, particulate removal, Semi-fine filter requirements, direct selection of microporous membrane, microporous membrane filter may filter can achieve the purpose of sterile filtration). The machine filter area, flow, large scope, so in the pharmaceutical, chemical, food and other industries have wide application, the application of pharmaceutical injection liquid filtration, very good results.
Model | Filter press | Plate size | Cake thickness | Filter chamber volume | Plate NO | Filtration pressure | Motor power | Weight | Dimensions L*W*H(mm) | Foundation Size(mm) | ||||
L | B | D | H | |||||||||||
X_M^AG30/870−U_K^B | 30 | 870*870 | ≤35 | 498 | 23 | ≥0.8 | 2.2 | 3046 | 3880*1250*1300 | 2920 | 700 | 1270 | 785 | |
X_M^AG40/870−U_K^B | 40 | 623 | 29 | 3593 | 4270*1250*1300 | 3300 | ||||||||
X_M^AG50/870−U_K^B | 50 | 789 | 37 | 4057 | 4790*1250*1300 | 3820 | ||||||||
X_M^AG60/870−U_K^B | 60 | 955 | 45 | 4597 | 5310*1250*1300 | 4340 | ||||||||
X_M^AG70/870−U_K^B | 70 | 1121 | 53 | 5136 | 5830*1250*1300 | 4860 | ||||||||
X_M^AG80/870−U_K^B | 80 | 1287 | 61 | 5636 | 6350*1250*1300 | 5380 | ||||||||
X_M^AG50/1000−U_K^B | 50 | 1000*1000 | 776 | 27 | 4 | 4352 | 4270*1500*1400 | 3350 | 780 | 1400 | 870 | |||
X_M^AG60/1000−U_K^B | 60 | 943 | 33 | 4480 | 4700*1500*1400 | 3780 | ||||||||
X_M^AG70/1000−U_K^B | 70 | 1109 | 39 | 5263 | 5130*1500*1400 | 4210 | ||||||||
X_M^AG80/1000−U_K^B | 80 | 1275 | 45 | 5719 | 5560*1500*1400 | 4640 | ||||||||
X_M^AG100/1000−U_K^B | 100 | 1608 | 57 | 6555 | 6410*1500*1400 | 5490 | ||||||||
X_M^AG120/1000−U_K^B | 120 | 1941 | 69 | 7466 | 7260*1500*1400 | 6340 | ||||||||
X_M^AG80/1250−U_K^B | 80 | 1250*1250 | ≤40 | 1560 | 29 | 5.5 | 10900 | 4830*1800*1600 | 3960 | 850 | 1740 | 995 | ||
X_M^AG100/1250−U_K^B | 100 | 1975 | 37 | 11750 | 5440*1800*1600 | 4570 | ||||||||
X_M^AG120/1250−U_K^B | 120 | 2391 | 45 | 12600 | 6060*1800*1600 | 5180 | ||||||||
X_M^AG150/1250−U_K^B | 150 | 2911 | 55 | 13620 | 6820*1800*1600 | 5950 | ||||||||
X_M^AG160/1250−U_K^B | 160 | 3119 | 59 | 14470 | 7130*1800*1600 | 6255 | ||||||||
X_M^AG200/1250−U_K^B | 200 | 3847 | 73 | 15320 | 8200*1800*1600 | 7325 | ||||||||
X_M^AG240/1250−U_K^B | 240 | 4679 | 89 | 16170 | 9420*1800*1600 | 8550 | ||||||||
X_M^AG250/1250−U_K^B | 250 | 4783 | 91 | 17020 | 9570*1800*1600 | 8700 | ||||||||
X_M^AG200/1500−U_K^B | 200 | 1500*1500 | 3809 | 49 | 11 | 26120 | 7140*2200*1820 | 5870 | 1170 | 1990 | 1070 | |||
X_M^AG250/1500−U_K^B | 250 | 4723 | 61 | 26930 | 7730*2200*1820 | 6860 | ||||||||
X_M^AG300/1500−U_K^B | 300 | 5637 | 73 | 28160 | 8720*2200*1820 | 7850 | ||||||||
X_M^AG350/1500−U_K^B | 350 | 6551 | 85 | 29600 | 10110*2200*1820 | 9090 | ||||||||
X_M^AG400/1500−U_K^B | 400 | 7618 | 99 | 31500 | 11260*2200*1820 | 10240 | ||||||||
X_M^AG450/1500−U_K^B | 450 | 8532 | 111 | 33400 | 12250*2200*1820 | 11230 | ||||||||
X_M^AG500/1500−U_K^B | 500 | 9446 | 123 | 33380 | 13240*2200*1820 | 12220 | ||||||||
X_M^AG600/2000−U_K^B | 600 | 2000*2000 | 11901 | 85 | 15 | 54164 | 13030*3000*2500 | 10610 | 1660 | 2000 | 1050 | |||
X_M^AG700/2000−U_K^B | 700 | 13838 | 99 | 58300 | 14390*3000*2500 | 11920 | ||||||||
X_M^AG800/2000−U_K^B | 800 | 14945 | 107 | 62460 | 15770*3000*2500 | 13240 | ||||||||
X_M^AG900/2000−U_K^B | 900 | 17713 | 127 | 66620 | 17150*3000*2500 | 14560 | ||||||||
X_M^AG1000/2000−U_K^B | 1000 | 19651 | 141 | 70780 | 18530*3000*2500 | 15880 |
Contact Person: Yuwei
Tel: +8613916133040